Application – Double-acting cylinders
Actuation – Solenoid operated, 115 volt, 50/60 Hz.
Functions – « Advance, » « hold » and « return. » The Posi-Check® feature holds the load when shifting from the « advance » to the « hold » position.
Used on these pumps – PE17, PE21, PE30 (with carrying handles removed), PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.
NOTE: A Pressure Switch and/or Gauge (Analog or Digital) may be attached to valves if desired.
NOTE: Valves are shipped without control switch.
CAUTION: To prevent sudden, uncontrolled descent of a load as it is being lowered, use a Load Lowering Valve (No. 9596) or Counter Balance Valve (No. 9720) in conjunction with the directional valve used in your application.
IMPORTANT: Conversion kit 251528 must be used when mounting the 9609 valve on PA17 or PE17 pumps.
IMPORTANT: When ordering any valve for a PE30 or PG30 series pump, ½†longer mounting screws are required.
For valves 9513 and 9519, order four 11956 cap screws.
For valves 9523, 9553 and 9589, order four 10855 cap screws.
For valves 9522, 9590 and 9615, order four 10854 cap screws.
Order No. | Cylinder Application * |
Operation | Valve Type | Volt | Advance / Return | Advance / Hold Return | Posi-Check® Feature | Weight (lbs.) |
---|---|---|---|---|---|---|---|---|
9512 | D.A. | Solenoid | 4-way, 3 Pos. Tandem Center | 24 | No | Yes | Yes | 18.1 |
9513 | D.A. | Solenoid | 4-way, 3 Pos. Tandem Center | 115 | No | Yes | Yes | 18.1 |
9516 | D.A. | Solenoid | 4-way, 3 Pos. Tandem Center | 12DC | No | Yes | Yes | 18.1 |
9519 | D.A. | Solenoid | 4-way, 3 Pos. Tandem Center | 230 | No | Yes | Yes | 18.1 |
* « D.A. » represents double-acting cylinders. |
Catalog | |
Parts List | |