Application: Used when one cylinder in a multi-cylinder application must advance before any other.
Operation: Pump is connected to port “P†and separate cylinders to ports “A†and “Bâ€. When pressure is applied to port “Pâ€, cylinder “A†advances. Cylinder “B†will not advance until a predetermined pressure setting is reached in cylinder “Aâ€. Pressure setting is adjustable from 500 to 8,000 psi with adjustment screw; factory preset at 1,000 psi. Has 3/8″ NPTF ports.
Order No. | Cylinder Application * |
Operation | Valve Type | Volt | Advance / Return | Advance / Hold Return | Posi-Check® Feature | Weight (lbs) |
---|---|---|---|---|---|---|---|---|
9597 | S.A. & D.A. | Automatic | Sequence Valve | — | — | — | — | 5.6 |
* “S.A.†represents single-acting cylinders, “D.A.†represents double-acting cylinders |
Catalog | |