Application – Manual operation for load lifting and holding with single-acting cylinders; automatic “dump†for operating hydraulic tools.
Actuation – Flipper lever/pilot oil.
Functions – With lever in closed position, valve will hold the load. When lever is “openâ€, valve functions as a true automatic “dump†valve.
Used on these pumps – Furnished with pilot lines and adapters for PA55, PA90, PE30, PE55, PE90 and PE120 series. For application on other pumps, consult factory.
NOTE: A Pressure Switch and/or Gauge (Analog or Digital) may be attached to this valve.
CAUTION: To prevent sudden, uncontrolled descent of a load as it is being lowered, use a Load Lowering Valve (No. 9596) or Counter Balance Valve (No. 9720) in conjunction with the directional valve used in your application.
IMPORTANT: When ordering any valve for a PE30 or PG30 series pump, ½†longer mounting screws are required.
For valves 9504, 9584, 9610 and 9610A, order four 12001 cap screws.
For valve 9582, order two 12001 and two 10856 cap screws.
Order No. | Cylinder Application * |
Operation | Valve Type | Volt | Advance / Return | Advance / Hold Return | Posi-Check® Feature | Weight (lbs.) |
---|---|---|---|---|---|---|---|---|
9610A | S.A. | Manual | 2/3-way, 2 Pos. | — | No | Yes | No | 4.4 |
* “S.A.†represents single-acting cylinders |
Catalog | |
Operating Instructions | |